Operation Manual

19EN
TOSHIBA RAS-07/10/13UKP (US) 1075000802
AIR CONDITIONER OPERATIONS AND PERFORMANCE
Cooling operation
Dry operation
If the air conditioner is used in conditions other than above, safety protection features may come into operation.
Three-minute protection feature
A protection feature prevents the air conditioner from being activated for approximately 3 minutes when it is
restarted immediately after operation or when the power supply switch is set to on. This will protect the machine.
Power failure
Power failure during operation will stop the unit completely.
The OPERATION lamp (green) on the indoor unit will start flashing when power is restored.
To restart operation, push the START/STOP button on the remote control.
Lightning or a car wireless telephone operating nearby may cause the unit to malfunction. Turn the power
supply switch to off and then to on. Push the START/STOP button on the remote control to restart.
Air conditioner operating conditions
For proper performance, operate the air conditioner under the following temperature conditions:
Outdoor temperature: 15°C to 43°C
Room temperature: 21°C to 32°C
CAUTION
Room relative humidity less than 80%. If the air conditioner
operates in excess of this figure, the surface of the air conditioner
may attract condensation.
Outdoor temperature: 15°C to 43°C
Room temperature: 17°C to 32°C
01RAS-07/10/13UKP P13-19 2/1/02, 12:04 AM19