Owner's Manual

2. PRINTER SETUP ENGLISH VERSION EO1-33089
2.6 Printer Setting
E2-21
2.6.2 Parameter Setting
(Cont.)
(11) WEB PRINTER
This parameter is to choose whether to use the printer as a web printer.
When the web printer is enabled, the status of the printer connected to
a network can be monitored through the web browser.
OFF Disables web printer function
ON INTERNAL Enables web printer function (using an internal
memory)
ON EXTERNAL Enables web printer function (using an external
memory)
(12) RBN NEAR END
This parameter is to choose the remaining ribbon length where the
ribbon near end is detected.
OFF Ribbon near end is not detected.
30m Ribbon near end is detected when the remaining
ribbon is 30-m long. (Equivalent to ribbon diameter
of 38 mm)
70m Ribbon near end is detected when the remaining
ribbon is 70-m long. (Equivalent to ribbon diameter
of 43 mm)
(13) EX.I/O
This parameter is to choose a type of the expansion I/O interface
operating mode. This parameter needs to be set depending on the
expansion I/O control specification of the device to be connected via
the expansion I/O interface.
TYPE1 Standard mode
TYPE2 In-line mode
(14) LBL/RBN END
This parameter is to choose a printer processing when a label end or
ribbon end is detected.
TYPE1 When a label/ribbon end is detected in the middle of
printing, the printer immediately stops printing.
TYPE2 Selectable only when the ribbon saving function is
not activated.
When a label/ribbon end is detected in the middle of
printing, the printer prints the half-finished label as
far as possible, and stops when the next label is at the
home position.
(15) MAXI CODE
This parameter is to choose a Maxicode specification.
TYPE1 Compatible with the current version
TYPE2 Special specification
NOTE:
The type specified by the
command may differ from the
actual mode, depending on the
status of this parameter. Also,
the data transmission method
differs partly.
F
or details, refer to the External
E
quipment Interface
Specification.
NOTE:
Since a detected remaining
ribbon length has some margin of
error, use the specified length as
a guide.