User Manual

MegaRAID Configuration Console
Config View
27
Each field is described in the table below:
To exit this page, click on “Config View” or “Scan Devices”.
Field Description
Firmware This field gives the firmware version of the physical drive.
Status This field gives the status of the physical drive. (online or
offline)
Errors This field gives the number of errors in the physical drive.
S.M.A.R.T.
Status
This field gives the S.M.A.R.T. (Self-Monitoring Analysis
and Reporting Technology) status of the physical drive. The
options for this are Disabled , OK, or Error. Disabled means
S.M.A.R.T. is off and physical drive does not collect statisti-
cal data. OK means S.M.A.R.T. is on and no errors found.
Error status means S.M.A.R.T. is on and some errors found,
this is serious warning that drive has to be replaced.
Logical Drive Not Available
Capacity This field gives the capacity of this physical drive.
Transfer Mode This field gives the type of transfer mode used on this physi-
cal drive.
Part of Array This field gives the part of the array that this physical drive
belongs to.
Connection This field gives the type of IDE connection that is used to
connect this drive to the RAID controller. (primary or second-
ary, master or slave)
Model This field gives the model number of the physical drive.
Serial Number This field gives the serial number of the physical drive.