Twin Cylinder Engine Service Manual
February 2017 - Digital Edition
ELECTRICAL SYSTEM AND COMPONENTS
Charging System Testing (Cont.)
AC Volts Output at Leads
1. Engine running at Top No-Load RPM (3300 RPM).
2. Set Digital Multi-Meter to AC volts.
3. Connect both Digital Multi-Meter leads to each stator lead.
4. Measured AC volts. Expected reading should be minimum of 30 VAC at top no-load RPM.
5. If measure voltage is below 30 volts AC, inspect ywheel for broken or cracked magnets.
6. Replace ywheel if magnets are damaged.
7. Repeat step 4.
8. If measured voltage is still below 30 volts AC replace stator.