Service Manual
ELECTRICAL
7-7Toro Z Master G3 3000/5000/6000 Series Service Manual
7
SeatSwitch
Purpose
The switch is in the safety circuit. If the engine is running
and the operator vacates the seat with either the PTO or
the parking brake disengaged, the engine will shut down.
Note: Thereisadelaymoduleinthesystem,
locatedinthehourmetermodule;therewill
beaslightdelaybeforetheengineshuts
downaftertheoperatorvacatestheseat.
Location
The seat switch is mounted under the seat to the seat
frame (Fig. 494).
Fig.494 PICT-0398a
HowItWorks
When the seat is vacated, the switch is open and there
should be NO continuity between the two terminals.
When the seat is occupied, the switch closes and there
should be continuity between the two terminals (Fig.
495).
Testing
1. Disconnect the switch from the wiring harness.
2. Using a VOM, check rst to ensure there is NO
continuity between either terminal, plunger out.
3. With the plunger pushed in, there should be
continuity between the terminals.