Operator's Manual

CheckSparkArrester(if
equipped)
ServiceInterval:Every50hours
WARNING
Hotexhaustsystemcomponentsmayignite
gasolinevaporsevenaftertheengineisstopped.
Hotparticlesexhaustedduringengineoperation
mayigniteammablematerials.Firemayresultin
personalinjuryorpropertydamage.
DoNotrefuelorrunengineunlesssparkarrester
isinstalled.
1.Stopengine,waitforallmovingpartstostop,and
removekey.Engageparkingbrake.
2.Waitformufertocool.
3.Ifanybreaksinthescreenorweldsareobserved,
replacethearrester.
4.Ifpluggingofthescreenisobserved,removethe
arresterandshakelooseparticlesoutofthearrester
andcleanscreenwithawirebrush(soakinsolventif
necessary).Reinstallarresteronexhaustoutlet.
FuelSystem
Maintenance
ReplacingtheFuelFilter
ServiceInterval:Every500hours/Yearly(whichever
comesrst)(moreoftenindirtyor
dustyconditions).
Thefuellterislocatedneartheengineonthefront
orrearsideoftheengine.
1.DisengagethePTO,movethemotioncontrollevers
totheneutrallockedposition,andsettheparking
brake.
2.Stoptheengine,removethekey,andwaitforall
movingpartstostopbeforeleavingtheoperating
position.
3.Allowthemachinetocooldown.
4.Stoptheengine,removethekey,andwaitforall
movingpartstostopbeforeleavingtheoperating
position.
5.Closethefuelshutoffvalveundertheseat
(Figure53).
G008963
12
3
Figure53
1.Fuellter
3.Fuelline
2.Hoseclamp
6.Squeezetheendsofthehoseclampstogetherand
slidethemawayfromthelter(Figure53).
7.Removethelterfromthefuellines.
8.Installanewlterandmovethehoseclampsclose
tothelter(
Figure53).
9.Openthefuelshutoffvalve.
38