ReplacingtheHydraulicFiltersand
HydraulicOil
ServiceInterval:Every250hours—Changethe
hydraulicltersandhydraulicoil
whenusingMobil1oil.
Every500hours—Changethe
hydraulicltersandhydraulicoil
whenusingToro
®
HYPR-OIL
™
500
hydraulicoil
Toreplacethehydraulicoil,theltersneedtobe
removed.Replacebothatthesametime.
1.Disengagethebladecontrolswitch(PTO),movethe
motioncontrolleverstotheneutrallockedposition
andsettheparkingbrake.
2.Stoptheengine,removethekey,andwaitforall
movingpartstostopbeforeleavingtheoperating
position.
3.Raisethemachineandsupportitwithjackstands
(
Figure83).
Figure83
1.Jackstands
4.Removeboththemowerbeltandthepumpdrive
belt.Thiswillpreventoilgettingonthebelts.Refer
toBeltsintheMaintenanceSection.
5.Placeadrainpanunderthelter,removetheold
lterandwipethesurfaceclean(Figure84).
53