Software Guide

ManuallyResettingMaintenance
Reminders
ToaccesstheServiceEnginescreenyoumust
disengagetheblade-controlswitch(PTO),movethe
motion-controlleverstotheNEUTRAL-LOCKposition,
andengagetheparkingbrake.
Sitintheoperator’sseat.Then,youcanenterthe
engineservicereminderresetmodebycycling
thekeyswitchbetweentheRUNpositionandOFF
position4timeswithin8seconds,withallthe
safetyinterlocksintheSAFEposition.
WhentheServiceEnginescreendisplaysand
ashes,youcanresettheengineoilmaintenance
reminderbycyclingeither1orbothmotion-control
leversfromtheNEUTRAL-LOCKpositiontothe
NEUTRALposition,andbacktotheNEUTRAL-LOCK
position.Oncethereminderresets,thescreen
exitstheServiceEnginescreenandreturnsto
thedefaultscreen.
YoucanexittheServiceEnginescreenatany
timebyturningthekeytoeithertheOFForSTART
position.
Sitintheoperator’sseat.Then,youcanenter
thetransmissionuidmaintenancereminderreset
modebycyclingthekeyswitchfromtheRUN
positiontotheOFFpositionandbacktotheRUN
position6timeswithin8seconds,withallthe
safetyinterlocksintheSAFEposition.
WhentheServiceTransmissionscreendisplays
andashes,youcanresetthetransmissionuid
maintenancereminderbycyclingeither1orboth
motion-controlleversfromtheNEUTRAL-LOCK
positiontotheNEUTRALposition,andbacktothe
NEUTRAL-LOCKposition.
YoucanexittheServiceTransmissionscreen
atanytimebyturningthekeytoeithertheOFF
orSTARTposition.
AlertsandErrorMessages
Thesystemiscapableofdisplayingthefollowing
errors:
VoltageError
Whenthekey-runvoltageislessthan12.3Vor
greaterthan16V,avoltageerrorashes.The
LEDashesaredlight.
g030966
Figure12
LowFuelLevelError
Ifthefuelsenderisinstalled,anerrorappears
whenthefuellevelis1/8orless.TheLEDashes
aredlightandthefuel-levelsymbolonthedefault
screenashes.
g031204
Figure13
PowertoRunOutputOver-CurrentError
Ifanover-currentoccurs,thenumber“2”displays
inthelower,leftcornerofthescreen.TheLED
ashesaredlight.
g030968
Figure14
1.Number“2”displays
8