Manual

Incorrect battery cablerouting could damage
themachineandcablescausingsparks. Sparks
cancausethe battery gassesto explode,
resulting in personalinjury.
Mways disconnect the negative (black)
battery cable before disconnecting the
positive (red) cable.
Mways connect the positive (red) battery
cable before connecting the negative (black)
cable.
5. Slide the rubber cover up the positive (red) cable.
Disconnect the positNe (red) cable from the battery
post (Figure 38). Retain all fasteners.
6. Rcmove the battery hold-down (Figure 38) and lift
the battery from the battery tra>
2 6
5
G005072
Figure 38
1. Battery
2. Positive battery post
3. Bolt, washer, and nut
4. Terminal boot
5. Negative battery post
6. Wing nut, washer, and bolt
7. Battery hold-down
Charging the Battery
Service Interval: Before storage--Charge the battery
and disconnect battery cables.
1. Remove the battery from the chassis; refer to
Removing the Batter>
2. Charge the battery for a minimum of 1 hour at 6 to
1() amps. Do not overcharge the batter>
3. When the battery is fully charged, unplug the charger
from the electrical outlet, then disconnect the
charger leads from the battery posts (Figure 39).
4
2
3
1
G000538
Figure 39
1. Positive battery post 3. Red (+) charger lead
2. Negative battery post 4. Black (-) charger lead
Note: Do not run the machine with the battery
disconnected, electrical damage may occur.
Installing the Battery
1. Position the battery in the tray (Figure 38).
2. Install the positive (red) battery cable to the positive
(÷) battery terminal using the fasteners removed
previousl>
3. Install the negatNe battery cable to the negative
(=) battery terminal using the fasteners removed
previousl>
4. Slide the red terminal boot onto the positive (red)
battery post.
5. Secure the battery with the hold=down (Figure 38).
6. Lower the seat.
Servicing the Fuses
The electrical system is protected by fuses. It requires
no maintenance; however, if a fuse blows, check the
component/circuit for a malfunction or short.
Fuse:
Main FI40 amp, blade=type
Charge Circuit F2-25 amp, blade=type
1. Remove the screws securing the control panel to the
machine. Retain all fasteners
.
.
Lift the control pane up to access the main wiring
harness and fuse block (Figure 40).
_l-breplace a fuse, pull out on the fuse to remove it
(Figure 40).
35