Operator's Manual

Figure72
1.Leftcableadjustment3.Platformdown
2.Rightcableadjustment
HydraulicSystem
Maintenance
ServicingtheHydraulic
System
HydraulicOilType:Toro
®
HYPR-OIL
500
hydraulicoilorMobil
®
115W-50syntheticmotoroil.
Important:Useoilspeciedorequivalent.Other
uidscouldcausesystemdamage.
HydraulicSystemOilCapacity:67oz.(2.0l)
CheckingtheHydraulicFluid
ServiceInterval:Aftertherst8hours
Every50hours
HydraulicOilType:Toro
®
HYPR-OIL
500
hydraulicoilorMobil
®
115W-50syntheticmotoroil.
Important:Useoilspeciedorequivalent.Other
uidscouldcausesystemdamage.
HydraulicSystemOilCapacity:67oz.(2.0l)
Note:Therearetwowaysofcheckingthehydraulicoil.
Oneiswhentheoiliswarmandoneiswhentheoilis
cold.Thebafeinsidethetankhastwolevelsdepending
iftheoiliswarmorcold.
1.Positionmachineonalevelsurface.
2.Disengagethepowertakeoff(PTO)andshutoff
theengine.
3.Waitforallmovingpartstostopbeforeleavingthe
operatingpositionandthensettheparkingbrake.
4.Cleanareaaroundcapandllerneckofhydraulic
tank(
Figure73).
g012685
1
2
3
4
Figure73
1.Cap3.Colduidlevel-full
2.Bafe4.Hotuidlevel-full
49