Service Manual
HYDRAULIC DRIVE SYSTEM
6-1136” & 40” Toro GrandStand Service Manual
6
Pump Installation
22. Remove the two sets of bolts and nuts securing
the pump control arm to the pump RTN (Return to
Neutral) assembly (Fig. 460).
1. Transferthehighpressurehoseidenticationmarks
to the replacement pump.
2. Secure the pump control arm to the RTN (Return
to Neutral) assembly using the bolts and nuts (Fig.
461).
21. Loosenthejamnutsecuringthesuctionhosetting,
thenremovethetting(Fig.459).
Fig. 459 DSCN-3032a
Fig. 460 DSCN-3038a
Fig. 461 DSCN-3038a
23. To service the pump, refer to the HydroGear Pump
Service Manual (BLN-52503).
3. Installthesuctionhosettingtothepump(Fig.462).
Note: Do not tighten the jam nut at this time.
Fig. 462 DSCN-3032a