ELECTRICAL
Operator Presence Switch (Seat Switch)
With the ignition switch in the RUN position, and the operator presence switch closed (operator is in the seat),
battery voltage is supplied to the neutral switches.
NOTE: The operator presence switch is part of the seat assembly.
Testing
1. Disconnect the wire harness from the Operator Presence Switch, located on the bottom of the seat assembly.
2. Using a digital multi-meter set to the OHM or Continuity setting, test the continuity between the two switch
terminals.
-When the seat is vacated, the switch should NOT have continuity (open).
-When the operator is present, the switch should have continuity (closed).
NORMALLY OPEN
OCCUPANT SWITCH
Figure 8