Service Manual

4-7Z Master Z400 Service Manual
4
Fig 169 PICT-0092a
14. Install the seat retainer rod (Fig. 169).
Fig 168 PICT-0087a
13. Install the cog belt onto the drive pulley. With a
spring puller, install the extension spring to the idler
arm assembly (Fig. 168).
HYDRAULIC SYSTEM
Replacing the Pump Drive Belt
15. Connect the negative battery cable to the battery.
16. Check the hydraulic uid in the reservoir tank. Add
oil if necessary. Air will need to be purged from
system. Follow the procedures for Purging the
Hydraulic System, page x-xx.
17. Check the neutral adjustment. Follow procedures for
Adjusting the Handle Neutral, page x-xx.
1. With a spring puller, remove the extension spring
from the idler arm assembly and remove the cog belt
from the pump drive and idler pulleys (Fig. 170).
Fig 170 PICT-0097a