Service Manual
310-2400/2600 IZT
24
LOWER HOUSING & FILTER
Refer to Figure 13.
DISASSEMBLY 310-2400
1. Remove the ten screws (50) holding the
lower housing (2) to the main housing (1),
and discard.
2. Remove the lower housing (2) and old
sealant. Take care not to damage the
casting surfaces.
3. Remove and discard the internal filter (46).
INSPECTION
1. Inspect the lower housing (2) for excessive
wear or damage.
ASSEMBLY
1. Install a new filter (46).
2. Apply sealant to the lower housing (2)
where the lower housing (2) mates with the
main housing (1). Refer to page 29.
3. Place the lower housing (2) on the main
housing (1).
4. Install the ten replacement screws (50) that
hold the lower housing (2) to the main hous-
ing (1).
5. Torque the ten screws (50) to the value
listed in Table 5.
50
2
1
46
Figure 13. Lower Housing & Filter 210-2400