Service Manual

5-11Z Master 500 Gas Series Service Manual
5
ENGINE
Note: The front left engine mounting bolt has two
ground cables (Fig. 192). Tighten the bolts.
Fig 192 DSC-2983
3. Install the mower drive belt around the electric PTO
clutch, refer to Replacing the Mower Belt page 7-24.
4. Plug the electric PTO clutch harness into the clutch
(Fig. 193). Secure the clutch wire to the PTO stop
rod with a tie strap.
Fig 193 DSC-2977
Fig 195 DSC-2978
6. Install the red heavy gauge wire from the solenoid to
the engine starter (Fig. 195).
Fig 194 DSC-2980
5. Connect the three wires going from the main
harness to the engine (Fig. 194).
Violet wire to the Regulator/Rectier
White wire to the Engine Magneto wire
Pink wire to the Fuel Solenoid
A. Violet Wire C. Pink Wire
B. White Wire
A
B
C