Service Manual

4-23Z Master Z597 Diesel Service Manual
4
HYDRAULIC SYSTEM
Fig 198 DSC-2370
12. Install the rear heat shield and tighten the bolts (Fig.
198).
13. Close the engine hood and latch. Start unit up and
operate for approximately 5 minutes and check the
oil level in the reservoir.
Note: Adjust handle neutral before setting pump
neutral. See Adjusting the Handle Neutral,
page 4-24.
This adjustment must be made with drive wheels turning.
Fig 199 DSC-2352
Fig 200 DSC-2357
2. Slide the seat fully forward, unlatch the seat and tilt
the seat forward (Fig. 200).
Setting the Hydrostatic Pump Neutral
1. Raise the frame and support the machine so drive
wheels can rotate freely (Fig. 199).