Service Manual

G-33
SM-E2B SERIES, WSM
G GENERAL
NOTE
The following special tools are not provided, so make them referring to the figure.
Injection Pump Pressure Tester
Application: Use to check fuel tightness of injection pumps.
W10252400
Valve Guide Replacing Tool
Application: Use to press out and press fit the valve guide.
W10250170
A
Pressure gauge full scale : More than 29.4 MPa
(300 kgf/cm
2
, 4267 psi)
B PF 1/2
C Copper gasket
D Flange (Mateiral Steel)
E Hex. nut 27 mm (1.06 in.) across the plat
F Adhesive application
G Fillet welding on the enter circumference
H Retaining nut
I 17 mm dia. (0.67 in. dia.)
J 8 mm dia. (0.31 in. dia.)
K 1.0 mm (0.039 in.)
L 17 mm dia. (0.67 in. dia.)
M 6.10 to 6.20 mm dia. (0.2402 to 0.2441 in. dia.)
N 8 mm (0.31 in.)
O 4 mm (0.16 in.)
P 11.97 to 11.99 mm dia. (0.4713 to 0.4720 in. dia.)
Q PF 1/2
R 23 mm (0.91 in.)
S 17 mm (0.67 in.)
T 4 mm (0.16 in.)
U 12.00 to 12.02 mm dia. (0.4724 to 0.4732 in. dia.)
V 100 mm (3.94 in.)
W M12 × P1.5
X 5 mm (0.20 in.)
A 220 mm (8.66 in.)
B 80 mm (3.15 in.)
C 40 mm (1.58 in.)
D 20 mm dia. (0.79 in. dia.)
E 9.96 to 9.98 mm dia. (0.3921 to 0.3929 in. dia.)
F 5.5 to 5.7 mm dia. (0.2165 to 0.2244 in. dia.)
G 25 mm dia. (0.98 in. dia.)
H 6.0 to 6.1 mm dia. (0.236 to 0.240 in. dia.)
I 5 mm (0.197 in.)
J 18 mm dia. (0.71 in. dia.)
K 10.6 to 10.7 mm dia. (0.417 to 0.421 in. dia.)
L 6.9 to 7.1 mm (0.272 to 0.280 in.)
C1 Chamfer 1.0 mm (0.039 in.)
C2 Chamfer 2.0 mm (0.079 in.)
C0.3 Chamfer 0.3 mm (0.012 in.)
KiSC issued 06, 2006 A