16. Tighten the jam nuts at the ball joints (Fig. 332).
Fig 332 PICT-3486a
19. Install the seat rod and lower the seat into position.
20. Lower the machine.
17. After both pump neutrals are set, shut off the
machine.
18. Remove the jumper wire from the wire harness ter-
minals and plug the terminals into the seat switch
(Fig. 333).