Service Manual

4-17Z Master 500 Gas Series Service Manual
4
5. To make the machine go left, turn the knob towards
the left side of the machine (Fig. 147, above).
6. Repeat this adjustment until the tracking is correct.
Fig 147 g. 57 m-6280
2. Stop the machine and set the parking brake.
3. Unlatch the seat and tilt the seat forward to access
the tracking knob.
Note: Determine the left and right sides of the
machine from normal operating position.
4. To make the machine go right, turn the knob towards
the right side of the machine (Fig. 147).
1. Pull the spring loaded idler down and remove
traction belt from the engine and hydro pump pulleys
(Fig. 148). Remove belt between the pulleys.
Replacing the Pump Drive Belt
Fig 148 DSC-3122
2. Install new belt around engine and hydro pump
pulleys (Fig. 149).
Fig 149 pump belt routing
3. Pull spring loaded idler down and align below
traction belt. Release pressure on spring loaded
idler.
HYDRAULIC SYSTEM
1. Pump rod 3. Tracking knob
2. Turn this way to 4. Turn this way to
track left track right