Service Manual
3-16 Z Master 500 Gas Series Service Manual
3
CHASSIS
12. When removing the lift lever grip assembly, you may
experience interference with the RH oor pan hinge
or the front edge of the RH motion control plate, or
both (Fig. 073).
Fig 073 DSC-1657
13. If the lift lever grip assembly contacts the RH oor
pan hinge, loosen the RH oor pan hinge mounting
hardware. Push the RH hinge upward. Re-tighten
the RH oor pan hinge mounting hardware (Fig.
074).
Fig 074 DSC-1661
Fig 072 DSC-1656
11. Remove retainer clip from lift lever grip assembly
(Fig. 072).
14. If the lift lever grip assembly contacts the RH motion
control plate, tilt and hold the oor pan assembly
slightly forward. Move the RH motion control lever
out of the neutral lock position and push it in the full
forward position. Using a tie strap or wire, tie the
oor pan assembly to the motion control arm to hold
the oor pan assembly in place (Fig. 075).
Fig 075 DSC-1665
A. RH Floor pan hinge B. RH Motion control plate
A
B