Service Manual

5-30 Z Master 500 Gas Series Service Manual
5
Fig 268 DSC-2823
20. Remove two bolts and nuts retaining the top and
bottom ribs and the bottom strap guard located on
the right side (Fig. 268). Remove the corresponding
bolts and nuts on the left hand side.
ENGINE
17. Unplug the two relays from the relay connectors.
Remove the two bolts and nuts retaining the
connectors to the right hand side plate (Fig. 265).
Fig 265 DSC-2818
Fig 267 DSC-2819
19. Remove the two bolts and nuts on the right side of
the machine used to hold the top rib to the right side
radiator brace (Fig. 267). Remove the corresponding
bolts and nuts on the left hand side.
Fig 266 DSC-2825
18. Remove the clamp and hose, located under the
coolant overow tank (Fig. 266).