Setup Instructions

fortherecommendedtimeintervaltobringthe
chargeuptoafullchargeof12.6Vorgreater.
Important:Ensurethatthenegativebattery
cableisdisconnectedandthebattery
chargerusedforchargingthebatteryshould
haveanoutputof16Vand7Aorless
toavoiddamagingthebattery(seethe
chartbelowfortherecommendedcharger
settings).Thisisespeciallyimportanton
KohlerEFI(ElectronicFuelInjection)units.
FailuretodosomaydamagetheECU
(ElectronicControlUnit).
Voltage
Reading
Percent
Charge
Maximum
Charger
Settings
Charging
Interval
12.6or
greater
100%16V/7A
Nocharging
required
12.4to12.6
75to100%16V/7A
30minutes
12.2to12.4
50to75%16V/7A
1hour
12.0to12.2
25to50%14.4V/4A
2hours
11.7to12.0
0to25%14.4V/4A
3hours
11.7orless
0%14.4V/2A
6hoursor
more
2.Connectthenegativebatterycable.
Note:Ifthepositivecableisalsodisconnected,
connectthepositive(red)cabletothepositive
batteryterminalrst,thenthenegative(black)
cabletothenegativebatteryterminal.Slipthe
insulatorbootoverthepositiveterminal.
Note:Iftimedoesnotpermitchargingthe
battery,orifchargingequipmentisnotavailable,
connectthenegativebatterycableandrunthe
machinecontinuouslyfor20to30minutesto
sufcientlychargethebattery.
7
CheckingtheWheelLug
NutTorque
NoPartsRequired
Procedure
Beforeyoustarttheengineandusethemachine,
checkthewheellugnuttorque;refertoCheckingthe
WheelLugNutsintheOperator'sManual.
4