Service Manual

ELECTRICAL
7-1Toro Z Master G3 3000/5000/6000 Series Service Manual
7
General
Note: InteractiveElectricalTroubleshootingDVD,
Part#492-9193isalsoavailable.
Purpose
Relay
There is one relay on this machine.
1. StartRelay: Functions as an electronic switch.
Once the safety connections are met, the relay will
activate completing the circuit to the starter solenoid.
Location
The relay is located on the frame, right side of the
engine, in front of the battery (Fig. 483).
Fig.483 DSCN-0008
HowItWorks
A relay is an electrically actuated switch.
1. Coil: Terminals 85 and 86 are connected to a coil.
Applying 12 volts to these terminals energizes the
coil turning it into an electromagnet.
2. Switch: Terminals 30, 87 and 87a are actually
part of a single pole, double throw (SPDT) switch.
Terminal 30 is the common lead. The switch is
spring loaded so that 30 and 87a are connected
when the coil is not energized. When the coil is
energized, the switch is “thrown” and terminals 30
and 87 are connected (Fig. 484).
Fig.484 DSC-2517a