Service Manual

HY13-1521-M2/US Service Manual
General Information Series HB Hydrostatic Transmission
Polish I.D. with emery
cloth paper
Remove any burrs with emery
cloth paper from the I.D. of
trunnion seal area. Clean
area with a lint free cloth after
polishing I.D.
Replacement Trunnion
seal
With the flat side of seal
facing up push seal in flush to
top housing.
Place socket on top of
seal
Place 11/16 deep well socket
over seal.
Tap seal into place
Gently tap socket with rubber
hammer driving seal into
place.
31
Parker Hannifin Corporation
Hydraulic Pump/Motor Division
Greeneville, Tennessee USA