Service Manual

Shaft, gear
10.Install PTO cmp onto housing(27) adjusting
forks of friction plates(45).
[Fig.11]
11.Install two bearings(48) and gear(47) onto
shaft(input(46). [Fig.12] (Shaft(input cmp)
12.Install two bearings(57) and gear(50),
seal ring(56) onto shaft(pump R(58).
[Fig.13] (Shaft(pump R cmp)
13.Install two bearings(57), gear(50), seal ring
(56) onto shaft(pump L(49). [Fig.14]
(Shaft(pump L cmp)
*Avoid damage of machined surfaces
(housing(27), gears, shafts).
*If damage is detected, seal ring(56) must be
replaced.
*When installing PTO cmp onto housing(27),
forks of three friction plates(98) fit grooves
of housing(27).
Fig.13
57
50
56
X2
58
Shaft(pump R cmp
Fig.14
Shaft(pump L cmp
57
50 56
X2
49
46
47 48
X2
Shaft(input cmp
Fig.12
27
Fig.11
PTO cmp