Service Manual

Switch
Part Numbers
Brake/PTO
Switch
88-9931
Purpose
NC2
Used as part of the safety interlock circuit, it is typically used to monitor the
NOS
position of the PTO or brake lever.
SPDT
Switch
How
It Works
(at
rest)
10081
This SPDT microswitch has three terminals. The lever is spring loaded in the
“up” position. When the lever on top of the switch is pushed, continuity
switches from COM
1
and NC2, to COM
1
and N03.
Testing
1.
Disconnect the switch from the harness.
2. Verify the conditions in the table.
10180
Switch
Part Numbers
lgnition
88-9830
Purpose
This component provides the proper switching for the starter, ignition, PTO,
How
It
Works
Detents inside the switch give
it
three positions:
off,
run and start. The start
position is spring loaded
so
the cylinder automatically returns to run once the
A
safety and accessory circuits.
Y
key is released.
X
Ignition
Switch
Note: The letters stamped on the terminals may be incorrect.
Testing
1. Disconnect the switch from the wiring harness.
2. Verify the following conditions in the table.
3. Check each of the terminals to case ground. None should show continu-
ity.
1
0253
n