Service Manual

Figure 1-3. Typical Ignition Switches.
2. If the unit is equipped with a primer bulb, FULLY
PRESS AND RELEASE the primer bulb 5 to 7
times (Figure 1-4).
Figure 1-4. Primer Bulb.
3. Place the choke knob or choke lever in the FULL
“CHOKE” position (Figure 1-5).
Figure 1-5. Typical Choke Controls.
4. Place the unit in the starting position (with the trim-
mer cutting head, cultivator tines, or blower nozzle
away from yourself and others).
5. Squeeze the throttle trigger to “FULL THROTTLE”
(Figure 1-6). Hold or lock the throttle in this posi-
tion.
Figure 1-6. Typical Throttle Control.
6. Pull the starter rope BRISKLY until you hear the en-
gine sound like it wants to run (normally 2 to 5
pulls).
7. Place the choke knob or choke lever in the “PAR-
TIAL” choke position (Figure 1-5).
8. Pull the starter rope BRISKLY 1 to 3 pulls to start
the engine.
Toggle
Switch
Slide
Switch
2.6078.003
2.6078.004
3.6078.005
3.6078.006
1
GENERAL INFORMATION
1-10