Operator's Manual

12Blinkonce,pause,blinktwice,long
pause,thenrepeat
VersionincompatibilityoftheBASE
and/orHH
Wrongsoftware(installthecorrect
softwarefromTORODIAG);contact
yourToroDistributor.
13Blinkonce,pause,blink3times,long
pause,thenrepeat
WrongHH—notimplementedon
RevA
Wrongproductassociation(i.e.
tryingtoupdatesoftwareona
MH–400withaProPasshandheld)
ResetingtheFaultCode
Aftersolvingtheproblem,resetthefaultcodesbydisconnectingandreconnectingdiagnosticconnectors.The
diagnosticlightwillashcontinuouslyat1Hz(1ashpersecond).
ExitingDiagnosticMode
1.PushtheE-STOPbuttondowntoturnoffthepower;refertoE-Stopbutton(page15).
2.Disconnectthediagnostic,shuntconnectors.
3.Pushthetetheredcapontothetwodiagnostic,shuntconnectors.
4.PulltheE-STOPuptoturnonthepower.
HandheldRemoteMessages(EHModelsOnly)
DisplayedMessageDescription
ASSOCPENDING
Associationyettobemade.
ASSOCACTIVE
Associationattemptinprogress.
POWERUPBASE
PoweruptheBaseUnit.
ASSOCPASSAssociationattemptwassuccessful.
ASSOCEXIT
ExitingAssociationmode
ASSOCFAILAssociationattemptfailed.
PRESSSTOREPresstheSTOREbutton.
ALLSTOREStoreallcurrentsetvaluesincurrentworkingmemory.
OPTIONSTOREStorethecurrentOptionsettingsincurrentworkingmemory.
BELTSTOREStorethecurrentFloorsettingsincurrentworkingmemory.
PRESET1STOREStorethecurrentPreset1settingincurrentworkingmemory.
PRESET2STOREStorethecurrentPreset2settingincurrentworkingmemory.
PRESET3STOREStorethecurrentPreset3settingincurrentworkingmemory.
WAITINGFORBASERemoteiswaitingforaBaseUnitresponse.
HOPPERUP
RemoteissendingHopperRaisecommand.
HOPPERDOWN
RemoteissendingHopperLowercommand.
PROPASSREVXX
Producttowhichthesystemissettocontrol.
MH400REVXXProducttowhichthesystemissettocontrol.
BATXX%
BatteryX.XV
Remainingbatterylifeinpercentage.
Remainingbatterylifeinvoltage.
CHANNELXChannelinGHzcurrentlybeingusedbythesystem.
HHIDXXXXXX
IdentityoftheHandheldRemote
BASEIDXXXXXXIdentityoftheBaseUnit
FLRXX%
OPTXX%
ThecurrentFloorspeedinpercent.
ThecurrentOptionspeedinpercent.