Software Guide

g211485
Figure81
1.Sprayer-controllericon
3.Flow-metericon
2.Expandicon
2.Setallofthespraysectionswitch(es)totheON
position.
3.SetthethrottletotheFASTposition.
4.SetthemastersectionswitchtotheONposition.
5.Selecttheow-metericon(Figure81).
Important:Ensurethecatchcontainer
isunderthenozzlebeforeturningonthe
sections.
6.Placethecatchcontainerunderthenozzle
beforeturningonthesections(Figure82).
g193177
Figure82
7.Turnonthesectionsusingthemaster-section
switch.
8.Performthecatchtestforatleast15-secondsor
moreat1ofthenozzles(Figure82).
Note:Thelengthofthecatchtestdependson
thesizeofthecontainer,butmoretimeisbest.
9.Shutoffthemastersectionswitch,setthe
throttletotheslowposition,andshutoffthe
spraypump.
10.Setthegraduatedcontaineronalevelsurface
andnotetheuidvolume(Figure83).
Important:Whenyouarereadingthe
graduatedcontainer,youmustsetthe
containeronalevelsurface.
Important:Whenyouarereadingthe
graduatedcontainer,readtheuidvolumein
thegraduatedcontaineratthelowestpoint
oftheuid-surfacecurve.
Important:Smallerrorsreadingtheuid
volumeinthegraduatedcontainerwill
signicantlyimpacttheaccuracyofthe
sprayercalibration.
g193829
Figure83
1.Highestpointofthe
uid-surfacecurve(donot
measurehere)
3.Levelsurface
2.Lowestpointofthe
uid-surfacecurve
(measurehere)
11.Usingtheuidamountfromthe1nozzle,
multiplythatamountbythenumberofnozzles
usedtosprayduringthecatchtest.Then
convertthatamountintolitersorgallons(128
ozequals1gallon).
Example:44ozX12nozzles=528oz/128
oz=4.125gallons
12.Entertheuidamountfromthecalculationwith
thekeypad(Figure84andFigure85).
34