FAULT VIEWER
Machine faults are generated by the Toro Electronic
Controllers (TEC) to identify an electrical system mal-
function (fault) that occurs during machine or spray sys-
tem operation. When a machine fault occurs, an audible
alarm will sound and the InfoCenter will display informa-
tion about the fault. Machine faults can be viewed via the
InfoCenter Fault Viewer (Fig. 37). See Machine Faults
in this chapter for additional information about specific
machine faults.
On machines with gasoline engines only, the Kubota En-
gine Control Unit (ECU) can also generate electrical
faults. The faults generated by the ECU are specific to
the engine and cannot be viewed via the fault viewer
(see Engine Faults in this chapter for additional informa-
tion).
The fault viewer displays the following information about
a machine fault:
CODE: fault code number
LAST: last time the fault occurred expressed in Key
ON hours
FIRST: first time the fault occurred expressed in Key
ON hours
NUM: number of times the fault has occurred
Scroll through the fault viewer screens by pressing but-
tons 1 or 2.
Return to the previous screen by pressing button 5
1. Button 1
2. Button 2
3. Button 3
4. Button 4
5. Button 5
6. Machine faults
Figure 37