Service Manual
Multi Pro 5800 Page 8 − 5 GeoLink Spray System
Special Tools
Quick Check Catch Jug − 64 oz (946 ml)
Use this container during flow calibration and spray noz-
zle catch tests.
NOTE: For most applications, a 32 oz (946 ml) catch jug
may be more accurate and easier to use.
IMPORTANT: When you are reading the graduated
container, you must set the container on a level sur-
face. Read the fluid volume in the graduated con-
tainer at the lowest point of the fluid−surface curve.
Small errors reading the fluid volume in the graduat-
ed container will significantly impact the accuracy
of the sprayer calibration.
Multi Pro 5800 sprayers using revision D software use
a variable timed catch test to achieve the target spray
volume. Revision D software is compatible with all Multi
Pro 5800 sprayers with serial numbers above
316000000.
Multi Pro 5800 sprayers using revision A, B and C soft-
ware use a fixed 15 second catch test time. The table in
Figure 2 lists the desired nozzle volume for a 15 second
catch test.
Toro Part Number: 131−7237
Figure 1
Nozzle Color
Ounces
Collected in
15 Seconds
(+/− ¼ oz)
Milliliters
Collected in
15 Seconds
(+/− 7.4 ml)
Yellow 6.4 189
Red 12.8 378
Brown 16.0 473
Gray 19.2 567
White 25.6 757
Blue 32.0 946
Green 48.0 1,419
Figure 2