Multi Pro 5800 Page 8 − 55 GeoLink Spray System
10.Set the graduated container on a level surface and
note the fluid volume.
IMPORTANT: When you are reading the graduated
container, you must set the container on a level sur-
face. Read the fluid volume at the lowest point of the
fluid−surface curve. Small errors reading the fluid
volume in the graduated container will significantly
impact the accuracy of the sprayer calibration.
11. Using the fluid amount from the 1 nozzle, multiply
that amount by the number of nozzles used to spray dur-
ing the catch test. Then convert that amount into liters
or gallons (128 fl oz equals 1 gallon).
Example: 44 fl oz X 12 nozzles = 528 fl oz / 128 fl oz =
4.125 gallons
12.Enter the fluid amount from the calculation with the
key pad (Fig. 60).
13.Confirm the flow cal factor.