Multi Pro 5800 Page 8 55 GeoLink Spray System
10.Set the graduated container on a level surface and
note the fluid volume.
IMPORTANT: When you are reading the graduated
container, you must set the container on a level sur-
face. Read the fluid volume at the lowest point of the
fluidsurface curve. Small errors reading the fluid
volume in the graduated container will significantly
impact the accuracy of the sprayer calibration.
11. Using the fluid amount from the 1 nozzle, multiply
that amount by the number of nozzles used to spray dur-
ing the catch test. Then convert that amount into liters
or gallons (128 fl oz equals 1 gallon).
Example: 44 fl oz X 12 nozzles = 528 fl oz / 128 fl oz =
4.125 gallons
12.Enter the fluid amount from the calculation with the
key pad (Fig. 60).
13.Confirm the flow cal factor.
1. Keypad
Figure 60
1