Service Manual

Multi Pro 5800 Page 10 3 Ultra Sonic Boom Kit (Optional)
CANbus Communications
Communication (diagnostics and reprogramming) with
the ultra sonic boom TEC controller is accomplished via
a separate Controller Area Network (CAN) bus system
not connected to the machine CANbus network. The
ultra sonic boom switch needs to be in the AUTOMATIC
or MANUAL position for the network to be active.
Two (2) specially designed, twisted wires form the CAN
bus. The engineering term for these cables are CAN
High and CAN Low. The bus wires for the 12 VDC cir-
cuits are black/white and red/white. At the ends of the
twisted pair of bus cables are two (2) 120 ohm termina-
tion resistors.
IMPORTANT: The termination resistor at the end of
the bus wires is required for proper electrical sys-
tem operation.
Precautions Concerning Chemicals Used in Spray System
Chemicals can injure persons, animals, plants, soil and
other property. To eliminate environmental damage and
personal injury:
1. Select the proper chemical for the job.
2. Carefully read the directions printed on the chemical
manufacturer’s labels before handling chemicals. In-
structions on chemical manufacturer’s container labels
regarding mixing proportions should be read and strictly
followed.
3. Keep spray material away from skin. If spray material
comes in contact with a person, wash it off immediately
in accordance with manufacturer’s recommendations
(refer to container labels and Material Safety Data
Sheets).
4. Always wear protective clothing, chemical resistant
gloves, eye protection and other personal protective
equipment as recommended by the chemical manufac-
turer.
5. Properly dispose of chemical containers, unused
chemicals and chemical solution.
Precautions for Removing or Adjusting Spray System Components
1. Park vehicle on a level surface and apply the parking
brake.
2. Shut off the vehicle’s engine and remove the key
from the ignition switch.
3. Disengage all power and wait until all moving parts
have stopped.
4. Remove chemicals from pump, hoses and other
spray components. Thoroughly neutralize and rinse
spray system before loosening or removing any spray
system component(s).
5. Make sure spray system pressure is relieved before
loosening any system component.