Software Guide

g192976
Figure50
Note:Thesprayersystemautomaticallyopens
thesectionvalve,thesprayernozzlessprayfor
thecatchtestperiod,andthesprayersystem
automaticallyshutsoffthesectionvalve.
5.Catchthewaterfromthesprayernozzleuntilthe
sprayerowshutsoff(Figure51).
g193177
Figure51
6.Setthegraduatedcontaineronalevelsurface
andnotetheuidvolume(Figure52).
Important:Whenyouarereadingthe
graduatedcontainer,youmustsetthe
containeronalevelsurface.
Important:Whenyouarereadingthe
graduatedcontainer,readtheuidvolumein
thegraduatedcontaineratthelowestpoint
oftheuid-surfacecurve.
Important:Smallerrorsreadingthe
uidvolumeinthegraduatedcontainer
signicantlyimpactstheaccuracyofthe
sprayercalibration.
g193416
Figure52
1.Highestpointofthe
uid-surfacecurve(donot
measurehere)
3.Levelsurface
2.Lowestpointofthe
uid-surfacecurve
(measurehere)
7.Comparethevolumeofuidinthegraduated
catchcontainerwiththeT argetVolumedisplayed
ontheInfoCenterscreen(Figure52).
Note:Youneedthevolumeofuidinthe
graduatedcatchcontainer±7.4ml(1/4oz)of
theT argetVolumedisplayedontheInfoCenter
screen.
8.Iftheuidlevelinthegraduatedcatchcontainer
is7.4ml(1/4oz)morethatthetargetvolume
or7.4ml(1/4oz)lessthanthetargetvolume,
perform1ofthefollowing:
Ifthevolumeofuidinthegraduatedcatch
containeris±7.4ml(1/4oz)oftheTarget
VolumedisplayedontheInfoCenterscreen,
pressbutton2.
Ifthevolumeistoolow,usethe
application-rateswitchtoraisethesprayer
19