Service Manual

Multi Pro 5800Page 8 98GeoLink Spray System
1. Install a new Oring in the sensor opening of the flow
meter body.
2. Place the rotor/magnet assembly in the flow meter
body with the magnets towards the sensor assembly.
Ensure the bottom rotor shaft is centered on the bearing
in the flow meter body.
3. Align the sensor assembly with the flow meter body.
The boss on the underside of one of the sensor assem-
bly mounting holes must align with the recess in the flow
meter body.
4. Secure the sensor assembly with the previously re-
moved fasteners. Do not overtighten the fasteners.
5. Use new Orings at each end of the flow meter body,
fit the flow meter assembly into the adapter fittings and
secure it with the previously removed forks.
6. Connect the flow meter to the wire harness.