Service Manual

Multi Pro 5800Page 6 38Electrical System
19
Spray System Fault flow meter not working correctly or
harness fault (No flow detected when based upon boom, pump
and pressure it indicates there should be)
Spray pump is ON,Master Boom switch is ON, at least one
boom is ON, spray pressure is above 20 PSI, the booms have
been on long enough for the system to stabilize and vehicle
speed is fast enough for automatic applicationrate control to
be enabled
Check the flow meter harness
for proper connection.
Confirm fluid flow at spray
nozzles. If so, flow should be
displayed on the flow rate me-
ter. If no fluid flow at spray
nozzles, begin checking the
spray system for a blockage.
Check flow meter for proper
function.
41 Spray System Fault Controller has detected a short circuit on
the spray pump PWM output circuit (TEC output 9 pin 44).
OR
Controller has determined an internal component in the
controller has overheated.
Check harness and associat-
ed components for a short to
ground
If fault persists, replace TEC
due to internal damage. Con-
tact your Authorized Toro Dis-
tributor