Service Manual

Multi Pro 5800Page 8 46GeoLink Spray System
AutoSteer Faults (Optional AutoSteer Only)
AutoSteer faults are generated by the by the Danfoss
EHi steering valve PVEDCLS controller to identify an
electrical system malfunction (fault) pertaining to the au-
tosteer system during operation. When an autosteer
fault occurs, an audible alarm will sound and the Info-
Center will display information about the fault (Fig. 53).
If an AutoSteer fault occurs:
1. Press any key to remove the fault information panel
from Operator Information Screen. The audible alarm
will continue to sound.
2. The fault description will be displayed on the Info-
Center (Fig. 54). Press button 3 to silence the audible
alarm. Press buttons 1 and 2 to scroll through the list of
active steering faults. Any active engine faults will be
displayed also.
3. Return to the previous screen by pressing button 5
An icon will appear in the upper left corner of the Opera-
tors Information screen as long as an autosteer fault is
active (Fig. 55). In order to clear the displayed fault, the
autosteer problem has to be resolved. Refer to the fol-
lowing Danfoss Error Codes table.
Note: Additional autosteer fault information may be
available by connecting a PC running the Danfoss
PLUS+1 Service Tool to the machines diagnostic port;
contact an Authorized Toro Distributor for assistance.
Figure 53
Figure 54
1. Button 1
2. Button 2
3. Button 3
4. Button 4
5. Button 5
6. Autosteer fault
description
1
2
3
4
5
6
1. ENG HRS 100 SHORT TO GND
SPN 520192 FMI 4
OCC CNT 1
1. Operator information
screen
2. Active fault icon
Figure 55
2
1