Multi Pro 5800 Page 6 41 Electrical System
Check Operation of Interlock Switches
CAUTION
Do not disconnect safety switches. They are for
the operator’s protection. Check the operation of
the interlock switches daily for proper operation.
Replace any malfunctioning switches before op-
erating the machine.
Your Multi Pro is equipped with a Toro Electronic Con-
troller (TEC) which monitors interlock switch operation.
If all of the interlock switches necessary to allow a spe-
cific machine operation are not in their desired position,
an Operator’s Advisory will appear on the InfoCenter
Display (see Operator’s Advisories in this chapter).
The interlock system used on your Multi Pro includes the
seat switch, the neutral switch, the brake pedal switch,
the spray pump enable switch and the optional clean
tank rinse pump switch (if equipped). Additional inter-
locks are incorporated into the various spray systems as
well. Spray system interlocks are discussed in the spe-
cific Spray System chapter in this manual.
Use the InfoCenter Display to test the various interlock
switches (TEC inputs) before physically testing the
switch and its circuitry (see InfoCenter display in this
chapter). Physically testing individual interlock switches
is included in the Component Testing section of this
Chapter.