Software Guide

g191701
g191700
Figure37
4.RotatetheignitionswitchtotheOFFposition
andthentotheONposition(Figure37).
g191705
Figure38
5.Pressbutton5tosaveyoursettingsandexit
theGEOLINKscreen,andreturntotheSETTINGS
screen(Figure38).
CalibratingtheSprayer
ApplicationRateMode
Note:Tocalibratethesprayerformanualmode
operation,refertosettingthesection—bypassvalves
intheOperatorsManualforthemachine.
1.Ensurethatthesprayertankisclean;referto
CleaningtheSprayerSystemintheOperators
Manual.
2.ToaccesstheCalibrationscreenpressbuttons
1or2ontheMAINMENUscreentonavigateto
theCALIBRATIONoption(Figure39).
g192024
Figure39
3.Pressbutton4toselectCalibrationsub-menu
(Figure39).
Note:Thisscreendisplaysandallowsyou
tocalibratetheowmeterinput,calibratethe
speedsensorinput,performaspeedtest,and
manuallyentercalculationdata.
FlowCalibration
Customerprovidedequipment:Useacatch
containergraduatedforthenozzle-owrateasfollows:
1.5Lpm(0.4gpm)orless-acontainergraduated
in10ml(1/2oz)incrementsispreferred.
1.9Lpm(0.5gpm)ormore-acontainergraduated
in20ml(1oz)increments.
Important:Youmustperformaowcalibration
for3sprayersectionseachtimeyoureplace
allnozzles,changetotheactivespray(down)
position,orafterreplacingtheowmeter.You
shouldperformaowcalibrationfor3sprayer
sectionsifyoureplaceseveralwornnozzles.
Note:Incorrectlyperformingthecatchtestresults
ininaccuracyinowcalibration.Theresultofthese
inaccuraciescausesthesprayersystemtoover-apply
orunder-applysprayerchemicals.
14