Operator's Manual

50
Problem Corrective ActionPossible Causes
The Area is inaccurate.
1. The sprayer width is not
correctly entered.
1. Check and set the appropriate
Width in the calibration mode.
2. The speed sensor is not
calibrated correctly.
2. Calibrate the speed sensor.
3. The speed sensor is damaged. 3. Contact your Authorized
Service Dealer.
The Distance is inaccurate.
1. The speed sensor is not
calibrated correctly.
1. Calibrate the speed sensor.
2. The speed sensor is damaged. 2. Contact your Authorized
Service Dealer.
The monitor does not display
Aliti Rt Ttl Vl
1. The monitor cable is loose. 1. Connect the monitor cable.
py
Application Rate or Total Volume.
2. The flow meter is dirty or
clogged.
2. Clean the flow meter.
3. The flow meter is not calibrated
correctly.
3. Calibrate the flowmeter
4. The flow meter is damaged. 4. Contact your Authorized
Service Dealer.
The Total Volume is inaccurate.
1. The flow meter is dirty or
clogged.
1. Clean the flow meter.
2. The flow meter is not calibrated
correctly.
2. Calibrate the flowmeter
3. The flow meter is damaged. 3. Contact your Authorized
Service Dealer.
The monitor displays 6553.5 when
in the Application Rate setting.
1. The monitor is not receiving
data from the speed sensor.
1. Contact your Authorized
Service Dealer.
The monitor is erratic in operation. 1. A two-way radio is too close to
the monitor or its cables.
1. Keep two-way radios away
from the monitor and its cables.
The displayed measurements do
not make sense.
1. The Units of Measurement is
set to a system other than what
you expect.
1. Check the Units of
Measurement to ensure that it
is set correctly.
The monitor reads “OFL.” 1. The data has exceeded the
maximum allowed.
1. Press and hold the [Reset]
button to clear the monitor.