Operator's Manual

9
CONSOLE PROGRAMMING:
After all installation procedures have been
completed and Console power is turned ON, the
Console will flash CAL in the RATE display. This
means you must calibrate or program the Console
before it can be operated. This is a one-time
operation which does not have to be repeated.
NOTE: Turning the POWER ON/OFF switch to
OFF does not affect the Console memory. All
data is retained.
While the calibration figures shown below are
useful guidelines, calculations should be carried
out for your particular machine and refined to
accommodate varying operating conditions and
desired applications.
DATA ENTRY:
When entering data into the console, the entry
sequence is always the same. (NOTE: DATA
MUST BE ENTERED INTO THE FIRST EIGHT
KEYS AFTER THE INITIAL CONSOLE
PROGRAMMING IS PERFORMED).
1. Depress the key in which you wish to enter
data.
2. Depress the ENTER key. An E will
illuminate in the DATA display.
3. Depress the keys corresponding to the
number you wish to enter (i.e., 1, 0, 2, 4).
The numbers will be displayed in the DATA display
as they are entered.
4. Complete the entry by again depressing the
ENTER key.
INITIAL CONSOLE PROGRAMMING:
If an entry selection error is made during steps
1,2,3, and 4, the Console can be reset by turning
off console power and turning console on while
depressing the
key.
1. Turn power on, the RATE window will flash
CAL. The DATA window will display US
a. Depressing momentarily
steps the
DATA display from US (acres) to SI [Hectares].
b. Depressing momentarily
steps the
DATA display from SI [Hectares] to TU.
c. Depressing momentarily
steps the
DATA display from TU (1,000 sq. ft.) to US.
2. Selecting US, SI or TU
a. To select US, SI or TU, step
until the
desired code is displayed in DATA display.
b. Momentarily depress
. The DATA
display will now display SP1.
3. Display SP1, SP2 or SP3 (Toro Multi Pro
1100 Pro Control uses wheel drive SP1).
a. Depressing momentarily
steps the
DATA display from SP1 (wheel drives, etc.) to
SP2 or SP3.
4. Selecting SP1.
a. To select SP1, step with
until SP1 is
displayed in DATA display.
b. Momentarily depress
the DATA
display will now display 0.
5. Enter BOOM 1 CAL 80 [204] in key labeled:
6. Enter BOOM 2 CAL 60 [152] in key labeled:
7. Enter Boom 3 CAL 80 [204] in key labeled:
8. Enter SPEED CAL in key labeled:
(Determined on page 5).
9. Enter METER CAL calibration number in key
labeled:
METER
CAL
5
. (This number is located on white
tag on Flow Meter Cable.
10. Enter VALVE CAL calibration number (2611)
in key labeled:
11. Enter the Application Target Rate in either
gallons per acre, liters per hectare or gallons per
1000 sq. ft. (selected in Step 2) you want to spray
in the key labeled:
12. Enter a second target application rate in either
gallons per acre, liters per hectare or gallons per
1000 sq. ft. (selected in Step 2) you want to spray
in key labeled
RATE 2
CAL
8
if desired.
NOTE: If you do not use a second rate, enter the
same rate in both RATE 1 and RATE 2.
YOU HAVE NOW COMPLETED PROGRAMMING
THE CONSOLE The flashing CAL will now
extinguish. If not, repeat procedure starting at
step 5.
See page 27 & 28 for Performance Verification &
Page 30 & 31 for Quick Referance Programming
Cards.
BEFORE SPRAYING