CheckingandAdjustingthe
Auger/ImpellerCable
ServiceInterval:Aftertherst2hours—Inspectthe
auger/impellercableandadjustitif
necessary.
Yearly—Inspecttheauger/impellercableand
adjustorreplaceitifnecessary.
1.Removethe2screwsthatareholdingthebelt
coverinplace(Figure34).
2.Removethebeltcover(Figure34).
g260066
Figure34
3.Withtheauger/impellerleverdisengaged,
ensurethatthegapbetweentheaugerclutch
armandtheframeofthemachineis1.5mm
(1/16inch)asshowninFigure35.
g260108
Figure35
1.1.5mm(1/16inch)
3.Augerclutcharm
2.Frame
4.Iftheauger/impellercableisnotproperly
adjusted,dothefollowingsteps:
5.Loosenthejamnut(Figure36).
g322960
Figure36
1.Jamnut2.Turnbuckle
6.Loosenortightentheturnbucklethatadjuststhe
tensiononthecable(Figure36).
7.Adjusttheturnbuckleuntilyouobtaintheproper
gap.
8.Tightenthejamnut.
9.Insertthe2screwsthatyoupreviouslyremoved
onthebeltcover.
10.Iftheauger/impellercableisproperlyadjusted
butaproblemremains,contactanAuthorized
ServiceDealer.