Service Manual
Single Stage Snowthrower Service Manual 6 - 1
ELECTRIC START SYSTEM
INTRODUCTION
The electric start single stage snowthrowers use a 120-
volt starting system. When the starter is supplied with
voltage, the helical shaft spins forcing the pinion gear
to slide out on the shaft and engage the ring gear.
CCR POWERLITE STARTER REMOVAL
1. Drain the fuel from the fuel tank using a pump type
siphon. Caution: Ignition of fuel can result in
severe personal injury of death. Store fuel in an
approved fuel storage container.
2. Remove the two bolts holding the upper shroud to
the front housing (Figure 130).
Figure 130 1854-26
3. Remove the two bolts (Figure 131) holding the
upper shroud to the handle.
Figure 131 1352-02
4. Remove the three bolts (Figure 132) to the starter
switch box.
Figure 132 1854-37
5. Lift upper shroud up and remove the wires to the
key switch (Figure 133).
Figure 133 1854-06
(A) Wires (B) Primer Hose
A
B