Service Manual

Table Of Contents
ProcedureforDeckMotorCaseDrainLeakageTest(continued)
12.Whentestingiscomplete,disconnecttesterfrommotorandhydraulichose.
Reconnectreturnhosetothedeckmotor.RemovecapfromthePTO
manifoldteettingorhydraulictubeandreconnectcasedrainhose.
13.Repeattestforadditionaldeckmotorsifrequired.
14.Whentestingiscomplete,makesurethatthehydraulictankisfullbefore
returningmachinetooperation.
GPM
Millilitersin15sec.
Ouncesin15sec.
0.1953.2
0.21896.4
0.32849.6
0.437812.8
0.547316.0
0.656819.2
0.766222.4
0.875625.6
0.985228.8
1.094632.0
Groundsmaster
®
5900&5910
Page5–59
HydraulicSystem:Testing
16227SLRevD