ChargingtheBattery(continued)
3.Followthebatterychargermanufacturer’sinstructions,connectthecharger
cablestothebattery.Ensurethatyoumakeagoodconnection.
4.Chargethebatteryfollowingthebatterychargermanufacturer’sinstructions.
5.Occasionallycheckthetemperatureofthebatteryelectrolyte.Ifthe
temperatureismorethan52°C(125°F)ortheelectrolyteisviolentlygassing
orspewing,lowerandtemporarilystopthechargingrate.
6.Threehoursbeforetheendofthecharging,measurethespecicgravityofa
batterycellonceperhour.
Note:Thebatteryisfullychargedwhenthecellsaregassingfreelyatalow
chargingrateandthereislessthana0.003changeinspecicgravityfor3
readings,1aftertheother.
BatteryChargeLevelSpecicGravityOpenCircuitVoltage
100%
1.26512.68
75%
1.22512.45
50%
1.19012.24
25%
1.15512.06
0%
1.12011.89
BatteryChargeLevelTable
BatteryChargeLevel(PercentofFullyCharged)
Battery
Reserve
capacity
(Minutes)
75%50%25%0%
80orless3.8hrs
@
3A
7.5hrs
@
3A
11.3hrs
@
3A
15hrs
@
3A
81to1255.3hrs
@
4A
10.5hrs
@
4A
15.8hrs
@
4A
21hrs
@
4A
126to1705.5hrs
@
5A
11hrs
@
5A
16.5hrs
@
5A
22hrs
@
5A
171to2505.8hrs
@
6A
11.5hrs
@
6A
17.3hrs
@
6A
23hrs
@
6A
above2506hrs
@
10A
12hrs
@
10A
18hrs
@
10A
24hrs
@
10A
Groundsmaster5900TractionUnit
Page5–107
ElectricalSystem:ServiceandRepairs
08159SLRevC