Service Manual

HighFlowHydraulicFilterKit
ToroPartNumber:TOR6011
Thehighowhydrauliclterkitisdesignedwith
largeow(150L/minuteor40gallons/minute)
andhighpressure(34,500kPaor5,000psi)
capabilities.Thiskitprovidesforbi-directional
ltrationwhichpreventslteredunwantedmaterial
fromenteringintothecircuitregardlessoftheow
direction.
Ifacomponentfailureoccursintheclosedloop
tractioncircuit,contaminationfromthedamaged
partwillremaininthecircuituntilyouremoveit.
Installahighowhydraulic-uidlterintothecircuit
whenyouconnectthehydraulictestgaugesin
ordertotestthetractioncircuitcomponentsorafter
youreplaceafailedtractioncircuitcomponent
(e.g.,pistonpumporwheelmotor).Thislter
removescontaminationfromthehydraulicuidin
thetractioncircuit,therebypreventingadditional
componentdamage.
Note:Thiskitdoesnotincludethehydraulichoses;
refertoHydraulicHoseKit(page2–13).
Note:ThereplacementlterelementisT oro
PartNo.TOR6012.Thelterelementcanister
tighteningtorqueis34N∙m(25ft-lb).
RemoteStarterSwitch
Afterushingthehydraulicsystemor
replacingahydrauliccomponent(e.g.
gearpump,pistonpump,drivemotor),itis
necessarytoprimethehydraulicpumps.
Aremotestarterswitchcanbeusedfor
thispurpose.Aremotestarterswitch
canbepurchasedlocallyorfabricatedas
follows.
IMPORTANT :Whenusinga
remotestarterswitch,itishighly
recommendedtoincludea20amp
in−linefusebetweenthebatteryand
switchconnectorforcircuitprotection.
Aremotestaterswitchcanalsobe
constructedusingToroswitch#106−2027,
alengthof14gaugewire,a20amp
in−linefuse,two(2)alligatorclipsand
necessaryconnectors.Connectingthe
wiretoswitchterminals1and2willallow
themomentaryswitchcontactstobeused
fortheremotestarterswitch.
Note:Forinformationonusingtheremote
starterswitchtoprimethehydraulic
pumps.
RemoteStarterSwitch(purchased)
RemoteStarterSwitch(fabricated)
Groundsmaster5900TractionUnit
Page2–15
SpecicationsandMaintenance:SpecialTools
08159SLRevC