Service Manual
Groundsmaster 360 Operator CabPage 8.1 − 13
(Rev. A)
Removal (Fig. 5)
1. Park machine on a level surface, lower cutting deck
or implement and stop engine. Remove key from the
ignition switch.
2. Locate A/C condenser fan assembly which is se-
cured to the frame under the rear of the cab headliner.
3. Disconnect the two (2) condenser fan plugs from the
wire harness connectors attached to the cab frame
(Fig. 6).
4. Support the condenser fan assembly to prevent it
from falling.
5. Remove two (2) knobs that secure condenser fan as-
sembly to machine (Fig. 6).
6. Lower condenser fan assembly from machine.
7. If necessary, disassemble condenser fan assembly
using Figure 7 as a guide.
Installation (Fig. 5)
1. If condenser fan assembly was disassembled, use
Figure 7 as a guide to secure fans to fan mount plate.
2. Raise and support fan assembly to cab frame.
3. Secure fan assembly to machine with two (2) knobs.
4. Connect the two (2) condenser fan plugs to the wire
harness connectors attached to the cab frame.
1. Condenser fan (2)
2. Knob (2)
3. Fan plug (2)
Figure 6
1
2
3
1. Fan mount plate
2. Screw (4 per fan)
3. Fan tab (4 per fan)
4. Condenser fan (2)
5. Plug (3)
Figure 7
5
4
1
2
3
4
Operator
Cab