Service Manual

LINKAGE
4-53Fixed Deck Mid-Size Service Manual
4
Fig 301 PICT-5549
Fig 303 PICT-5548
3. Install the nylon bushings onto each end of the OPC
rod (Fig. 301).
5. Align the setscrew with the at side of the rod and
install the OPC levers onto the ends of the OPC rod
(Fig. 303).
Fig 302 PICT-5559
4. Apply high strength thread locking compound
(Loctite 609 or equivalent) onto both ends of the
OPC rod (Fig. 302).
6. Apply thread locking compound to the set screws
(Fig. 304).
Fig 304 PICT-5562a