Operator's Manual
EngineMaintenance
ServicingtheAirCleaner
ServiceInterval:Every400hours
Checktheaircleanerbodyfordamagewhichcould
causeanairleak.Replaceifdamaged.Checkthe
wholeintakesystemforleaks,damageorloosehose
clamps.
Servicetheaircleanerlteronlywhentheservice
indicator(Figure27)requiresit.Changingtheairlter
beforeitisnecessaryonlyincreasesthechanceof
dirtenteringtheenginewhenthelterisremoved.
g009709
Figure27
1.Aircleanerindicator
Important:Besurethecoverisseatedcorrectly
andsealswiththeaircleanerbody.
1.Pullthelatchoutwardandrotatetheaircleaner
covercounterclockwise(Figure28).
g009710
Figure28
1.Aircleanerlatch2.Aircleanercover
2.Removethecoverfromtheaircleanerbody.
Beforeremovingthelter,uselowpressure
air(40psi,cleananddry)tohelpremove
largeaccumulationsofdebrispackedbetween
outsideofprimarylterandthecanister.Avoid
usinghighpressureairwhichcouldforce
dirtthroughthelterintotheintaketract.
Thiscleaningprocesspreventsdebrisfrom
migratingintotheintakewhentheprimarylter
isremoved.
3.Removeandreplacetheprimarylter(Figure
29).
Cleaningoftheusedelementisnot
recommendedduetothepossibilityofdamage
totheltermedia.Inspectthenewlterfor
shippingdamage,checkingthesealingendof
thelterandthebody.Donotuseadamaged
element.Insertthenewlterbyapplying
pressuretotheouterrimoftheelementtoseat
itinthecanister.Donotapplypressuretothe
exiblecenterofthelter.
g009711
Figure29
1.Aircleanerprimarylter
Important:Neverattempttocleanthesafety
lter(Figure30).Replacethesafetylter
withanewoneaftereverythreeprimarylter
services.
31