Service Manual

Groundsmaster 4500--D/4700--D
Page 3 -- 4
Kubota Diesel Engine (Rev. A)
Adjustments
Engine Run Solenoid
1. When ignition switch is in the RUN position, the en-
gine run solenoid should energize and position the fuel
stop lever to within 1/16” (1.6 mm) of stop on the injec-
tion pump.
2. If adjustment is needed, loosen lock nut and rotate
the threaded end of the swivel until the lever is properly
positioned.
3. Tighten lock nut. Recheck adjustment.
1. Run solenoid (ON)
2. Lever
3. Swivel
4. Lock nut
Figure 1
2
3
1
4
Figure 2
1. Run solenoid (OFF)
2. Solenoid lever
3. Injection pump stop
3
1
2